Stroke (mm) | 200 | 300 | 400 | 500 | 600 | 800 | 1000 |
a3 (mm) | 560 | 660 | 760 | 860 | 960 | 1160 | 1360 |
Drive type | Thrust (kN) | Rod speed (mm/s) | Motor power (kW) | Motor voltage (V) | Frequency (Hz) | Motor current (A) | Converter (kW) |
---|---|---|---|---|---|---|---|
Ball screw | 12.00 | 15 - 150 | 2.20 | 5-50 | 5.80 | 3.0 |
<<< back to list
Configuration A
Two adjustable End Positions
- Accurate approach to two adjustable end positions
- Adjustable acceleration and deceleration ramps
- Thrust limitation up to the preset maximum thrust
- Position signal Output
- Limitation of adjustment options for position parameters as a safety Feature
- Speed adjustment via potentiometer
- Fault output
Configuration B
8 selectable Positions
- Precise approach to 8 selectable positions
- Adjustable acceleration and deceleration ramps
- Thrust limitation up to the specified maximum thrust
- Position signal Output
- Limitation of adjustment options for position parameters as a safety Feature
- Speed adjustment via potentiometer
- Fault output
Configuration C
Analog Input for variable position
- Infinite variable stroke Position
- Adjustable acceleration and deceleration ramps
- Thrust limitation up to the specified maximum thrust
- Position signal Output
- Digital output "position reached"
- Speed adjustment via potentiometer
Configuration D
Thrust controlled Electric Actuator
- Infinite variable stroke Position
- Adjustable acceleration and deceleration ramps
- Thrust limitation up to the specified maximum thrust
- Position signal Output
- Digital output "position reached"
- Speed adjustment via potentiometer
Configuration E
Variable control via Field Bus interface
- Control of operating parameters (acceleration, thrust, position)
- Switchable control parameters, even under operating conditions
- Integration via field bus Interface
- Readout of operating parameters in digital Format
- Thrust limitation can be adjusted up to the maximum thrust
- Fault output
Synchronisation control
Synchronisation control
- Control of operating parameters (acceleration, thrust, position)
- Switchable control parameters, even under operating conditions
- Integration via field bus Interface
- Readout of operating parameters in digital Format
- Thrust limitation can be adjusted up to the maximum thrust
- Fault output